  • I/O board with 16 supervised inputs and 16 digital outputs 
  • For adding additional I/O boards to IOCB1616 enclosure or service replacement of existing board (maximum of 4 board/IOCB1616 per ACU) 
  • Works with Rev. 10 ACUs and higher 
  • New smaller board 
  • Inputs can monitor contacts on doors, motion sensors, push buttons, or other sensing devices 
  • Outputs can activate CCTV cameras, burglar alarm systems, lights, HVAC, parking lot gates, or other devices 
  • Single or multiple inputs can be assigned to trip single or multiple outputs – either open collector or optional form ""C"" relays – using any of the 7 different modes that include timers, delays, or pulsing 
  • Time zones can be assigned to activate and deactivate inputs or outputs 
  • The access control unit communicates to the IOCB1616 boards via RS485 over twisted pair cable 
  • Includes a black metal enclosure with ample room to mount multiple IOCB1616 board configurations for flexible installation and wiring 
  • Board only (without enclosure) also available. Part: IOCB1616b
Item#:
IOCB1616
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix MOM5 power distribution module converts one (1) non power-limited DC voltage input to five (5) power-limited outputs. Each output will route power to a variety of access control hardware and devices which includes Mag Locks, Electric Strikes, Magnetic Door Holders, etc. These outputs will operate in both fail-safe and fail-secure modes. Controlled trigger input is achieved through normally open (NO) or normally closed (NC) supervised input or the polarity reversal from an FACP (Fire Alarm Control Panel). A form "C" dry output relay will enable HVAC Shutdown, Elevator Recall or trigger auxiliary devices.

Features

  • Output relay indicates that unit is triggered (Form C contact rated 1A @ 28VDC).
  • Interfaces with most DC Power Supplies.

Item#:
MOM5