S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
- Three models available, providing varying degrees of low-voltage DC output
- Built-in overload protection
- Regulated and filtered output
- Green LED indicates power input
- Red and Blue LEDs indicate power output
Trove2 enclosure with THN2 Altronix/Honeywell NetAXS backplane:
Trove2 Enclosure
Altronix Trove Mercury kits are pre-assembled and consists of Trove1M1 enclosure/ backplane with factory installed Altronix power supply/charger and sub-assemblies. These kits also accommodates various combinations of Mercury boards for up to four (4) doors in a single enclosure. Trove simplifies board layout and wire management, reduces installation time and labor costs.
Trove1 enclosure with TSA1 Altronix/SALTO backplane:
Trove1 Enclosure:
Altronix T2MK3F8DQ is pre-assembled and consists of Trove2M2 enclosure with factory installed Altronix power supply/charger(s) and sub-assemblies. This kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure.
Altronix T2MK75F16DQ is pre-assembled and consists of Trove2M2 enclosure with factory installed Altronix power supply/charger(s) and sub-assemblies. This kit also accommodates various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.
Trove3 enclosure with TCV3 Altronix/CDVI backplane:
Trove3 Enclosure:
Input
- Voltage: 120VAC, 60Hz, 3.5A max.
- Fusing: 5A / 250V.
Output
- Voltage: Factory set at 24VDC.
- Current: 6A continuous.
- Maximum Supply Current for Main and Aux. Outputs on eFlow6NB Power Supply board, PDS8 Power Distribution Module’s and ACM4 Access Power Controller’s outputs is 5.6A.
- Auxiliary: Class 2 power-limited @ 1A (unswitched).
- Other: Overvoltage protection. Filtered and regulated.
- Built-in charger for sealed lead acid or gel type batteries (if batteries are required, install separate battery enclosure RE2).
- Automatic switch over to stand-by battery when AC fails.
- Zero voltage drop when unit switches over to battery backup (AC failure condition).
- Supervised: Latching or non latching.
- EOL: 10K Resistor.
- AC Failure: Form “C” contacts.
- Battery: Form “C” contacts.
- Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
- Input: 120VAC is present.
- DC Output: Powered.
- Battery: Discharged or not connected.
Input
- Voltage: 24VDC from eFlow6NB.
- Fusing: 10A / 250V.
Output
- Voltage: 24VDC.
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
- b) Four (4) dry form “C” 5A rated relay outputs.
- c) Any combination of the above.
- Four (4) auxiliary power outputs (unswitched).
- Fuses Rating: 3A / 32VDC.
Indicators (LED's)
- Red LEDs: Outputs are triggered (relays energized).
- Green LED: FACP disconnect is triggered.
Input
- Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
- Fusing: 10A / 250V.
Output
- Voltage: 12 or 24VDC individually selectable.
- Fuses Rating: 3A / 32VDC.
Indicators (LED)
- DC Output: Eight (8) individual output LEDs.