ActionsThe ELK-952 provides exceptional protection against damage from lightning, voltage spikes, and surge damage coming into a phone line. It installs between the RJ31X Phone Jack and the Security Control. The ELK-952 features multi-stage protection and is 5 times faster than MOVs.
- 5 Stage Surge Protection
- Very Economical
- Easy to Install
- Works with Any Security Control
- Response Time: < 1 nanosecond
- Max. Signal Voltage: 250V (peak)
- Breakdown Voltage: 280V (nominal)
- Max 'Peak' Pulse Current: 100 Amps
- Accommodates any manufacturer’s boards and equipment.
- Includes Altronix Trove1R Rack Enclosure and one (1) removable TBL1R backplane.
- 16 Gauge black powder coated steel enclosure with ample knockouts for convenient access.
- Includes: tamper switch, cam lock and mounting hardware. Modular 2U standard EIA 19” drawer with extendable slides up to 48”.
- IEC320 connector.
- Included Z Bracket facilitates ease of wiring.
Model VR1T converts a 24VAC or 24VDC input into a regulated 12VDC @ 1A output.
Features
Trove3 enclosure with THW3 Altronix/Honeywell backplane:
Trove3 Enclosure:
Trove3 enclosure with TCV3 Altronix/CDVI backplane:
Trove3 Enclosure:
Input
- Voltage: 120VAC, 60Hz, 3.5A max.
- Fusing: 5A / 250V.
Output
- Voltage: Factory set at 24VDC.
- Current: 6A continuous.
- Maximum Supply Current for Main and Aux. Outputs on eFlow6NB Power Supply board, PDS8 Power Distribution Module’s and ACM4 Access Power Controller’s outputs is 5.6A.
- Auxiliary: Class 2 power-limited @ 1A (unswitched).
- Other: Overvoltage protection. Filtered and regulated.
- Built-in charger for sealed lead acid or gel type batteries (if batteries are required, install separate battery enclosure RE2).
- Automatic switch over to stand-by battery when AC fails.
- Zero voltage drop when unit switches over to battery backup (AC failure condition).
- Supervised: Latching or non latching.
- EOL: 10K Resistor.
- AC Failure: Form “C” contacts.
- Battery: Form “C” contacts.
- Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
- Input: 120VAC is present.
- DC Output: Powered.
- Battery: Discharged or not connected.
Input
- Voltage: 24VDC from eFlow6NB.
- Fusing: 10A / 250V.
Output
- Voltage: 24VDC.
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
- b) Four (4) dry form “C” 5A rated relay outputs.
- c) Any combination of the above.
- Four (4) auxiliary power outputs (unswitched).
- Fuses Rating: 3A / 32VDC.
Indicators (LED's)
- Red LEDs: Outputs are triggered (relays energized).
- Green LED: FACP disconnect is triggered.
Input
- Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
- Fusing: 10A / 250V.
Output
- Voltage: 12 or 24VDC individually selectable.
- Fuses Rating: 3A / 32VDC.
Indicators (LED)
- DC Output: Eight (8) individual output LEDs.
Model VR1 converts a 24VAC or 24VDC input into a regulated 12VDC @ 1A output.
Features