S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
Actions- Integrated door control, proximity reader and keypad
- 2000 users
- 2000 event audit trail
- 32 doors per site (when managed with Hub Manager® Professional)
- Bi-color LED to indicate operation
- Weather resistant design
- Fits over a single gang electrical box
- Communication via – SEG-1 (LAN/WAN) or USB to 485 converter
- Remote proximity reader mounting and glass mount option
Altronix T3MK77F16D Trove Mercury kit is pre-assembled and consists of Trove enclosure with factory installed Altronix power supply/chargers and sub-assemblies. This kit accommodates various combinations of Mercury boards for up to sixteen (16) doors in a single enclosure.
- Input: 120VAC 60Hz/9.0A.
- Output:
- 24VDC @ 9.2A max current.
- Sixteen (16) Fail-Safe/Fail-Secure or Dry Form "C" Outputs
- Fully assembled kit includes:
- Trove3 enclosure with TM3 backplane
- Two (2) eFlow104NB - Power Supply/Chargers
- Two (2) ACM8CB - PTC Protected Access Power Controllers
- Two (2) PD8ULCB - PTC Protected Power Distribution Modules
- One (1) RSB2 - Rocker Switch Bracket with Two (2) Rocker Switches
- Back-up Battery:
- Capacity: 12AH / 12VDC (Up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure).
- Type - Sealed lead acid or gel type.
- Fuse Rating: 15A/32V
- Failover - Upon AC loss, instantaneous.
- Supervision:
- AC Failure - Form "C" contacts.
- Battery - Form "C" contacts.
- Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
- LED Indicators:
- Input - 120VAC is present.
- DC Output - Powered.
- Battery - Discharged or not connected.
- Faceplate
- 501LTE and 502 circuit boards
- 4G LTE antenna
- PS-12DC1 power supply
Reliable, durable and highly accurate ZK fingerprint sensor with ver. 10 algorithm provides less than 1.5 second user recognition. Works without computer. Complete setup and programming can be done via keypads and embedded firmware.Audio-Visual Indication for acceptance and rejection of valid/invalid fingerprints. Relay Outputs for electric lock and alarm. Inputs for door status sensor and exit switch. Supports multiple timezones and personnel groups for programming valid entry zones. IP65 rated waterproof enclosure permits this reader to be used for outdoor applications.
Can store up to 3000 fingerprint templates, 10,000 cards and 50000 transactions. The data can be backed up to a USB drive and transferred to another reader in the absence of computer connectivity. Internal Proximity Card or Mifare Card reader allows dual factor authentication for access control.
Features
- Rugged structure for outdoor installation and extra durability
- IP65 rated waterproof and weatherproof structure
- Slim and elegant design
- One of the worlds smallest fingerprint terminals
- Sleek and slim design for narrow spaces.
- Fast and accurate fingerprint algorithm
- Fingerprint identification in 1 second
- Stores 3000 fingerprint templates, 10,000 cards and 50000 transactions
- Easy installation and connectivity with Wiegand input and output and network interface by TCP/IP and RS485
- Full access control features include DLST, Web-server, Anti-Passback and access control interface for third party electric lock, door sensor, exit button and alarm
- Easy operation and management; works without computer and has built-in keypad and RF card reader for multi-modal authentication
- Special Order with Mifare card module
- Performance
- Independent button programming allows for different frequency and codes: Security+ 2.0 (Tri-band 310/315/390 MHz), Security+ 315 MHz and Security+ 390 MHz.
- Eliminates the need for multiple remotes when operating LiftMaster Garage Door Openers, Gate Operators, Commercial Door Operators, or MyQ® Accessories.
- Cloning capability of existing LiftMaster DIP Switch Remote Controls (61LM and 361LM) or a LiftMaster Encrypted DIP Switch Remote Control (811LM) to any button.Â
- Safety and Security
- Security+ 2.0 rolling code technology virtually eliminates radio interference and offers enhanced range, security and dependability.
- Security+ rolling code technology with every click a new code is sent.
- 120VAC 60Hz/9.0A.
- 24VDC @ 9.2A max current.
- Sixteen (16) Fail-Safe/Fail-Secure or Dry Form “C” Outputs
- Trove3 enclosure with TM3 backplane
- Two (2) eFlow104NB - Power Supply/Chargers
- Two (2) ACM8 - Fuse Protected Access Power Controllers
- Two (2) PD8UL - Fuse Protected Power Distribution Modules
- One (1) RSB2 - Rocker Switch Bracket with Two (2) Rocker Switches
- Capacity: 12AH / 12VDC (Up to 4 within enclosure); 40 AH / 65 AH (requires separate enclosure).
- Type - Sealed lead acid or gel type.
- Fuse Rating: 15A/32V
- Failover - Upon AC loss, instantaneous.
- AC Failure - Form “C” contacts.
- Battery - Form “C” contacts.
- Low DC Power Shutdown - Shuts down DC output terminals if battery voltage drops below 71-73% for 12V units and 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
- Input - 120VAC is present.
- DC Output - Powered.
- Battery - Discharged or not connected.
- Input 115VAC, 60Hz, 2.5A or 230VAC, 50Hz, 1.5A.
- Two (2) Normally Open (N.O.) trigger inputs (Input 1 and Input 2).
- FACP Normally Closed (N.C.) input.
- Two normally open ADA inputs for special mode of interfacing with automatic door operators.
- Two (2) 19.8VDC-26.4VDC rated individually controlled lock outputs configurable for fail-secure or fail-safe electronic locking hardware for applications with battery back-up. 24VDC-26.4VDC rated for applications without battery back-up (US applications only). Current rating 2A combined.
- One (1) 19.8VDC-26.4VDC @ 0.8A rated filtered regulated auxiliary output for applications with battery back-up, 24VDC-26.4VDC @ 0.8A rated for applications in US not requiring battery back-up. Not affected by FACP trigger.
- One (1) 12VDC filtered regulated auxiliary output rated 0.5A. Not affected by FACP trigger.
- Two (2) follower Normally Open relay outputs for controlling ADA actuators/accessories rated 28VDC @ 0.5A.
- Two momentary door operator activation relay outputs.
- Trouble relay output indicating low AC voltage trouble and battery trouble.
- Battery leads included.
- When 7AH batteries are used, battery capacity for emergency stand-by is 30 minutes.
- Built-in charger for sealed lead acid batteries.
- Maximum charge current 650mA.
- Automatic switch over to stand-by battery when AC fails.
- Green AC Power LED indicates AC presence.
- Red trigger output LEDs indicate panic device status / opened (activated, short circuit).
- Green Fire Alarm Interface (FAI) LED indicates FACP interface is activated.
- Red Battery LED indicates low battery during AC failure and battery test.
- Green AC status LED indicates loss of AC power.
- Normally Closed FACP trigger input.
Programmable Fire Alarm Disconnect options:
- Removes power to outputs and disables delayed follower relays.
- Connects power to lock outputs and enables delayed follower relays.
- 4G LTE cellular
- High-definition Ascent Camera for still photos
- Photo push notifications
- 2 Wiegand inputs
- Control via 6 different control methods
- Control up to 2 gates or doors
- Cloud-based access-control management
- Up to 10,000 app, text, and voice users
- Up to 1,000 keypad codes
- Rollover calling - up to 3 phone numbers per user
- Location-Based Access Control (LBAC)
- Push and/or email event and status notifications
- Ascent Connect integration
- 7-day timers
- Holiday timers
- Special-event timers
- Temporary users with permission limits
- Quick temporary-user setup
- Audit trail with detailed reports
- "Do Not Disturb" mode
- Drop-in directory insert
- Durable polycarbonate directory lens
- Powder-coated-steel enclosure and stainless-steel faceplate
- Nightlight, lighted keypad, and valet light
Input
- Voltage: 120VAC, 60Hz.
- Fusing: 5A / 250V.
Output
- Voltage: 24VDC.
- Current: 4A continuous.
- Other: Overvoltage protection. Filtered and regulated.
- Capacity: 7AH / 12VDC (Up to 2 within enclosure). 40 AH / 65 AH (requires separate enclosure).
- Type: Sealed lead acid or gel type.
- Fuse: Rating 10A/32V.
- Failover: Upon AC loss, instantaneous.
- AC Failure: Form “C” contacts.
- Battery: Form “C” contacts.
- Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
- Input: 120VAC is present.
- DC Output: Powered.
- Battery: Discharged or not connected.
Input
- Voltage: 24VDC from eFlow4NB.
Output
- Voltage: 12VDC.
- Current: 6A continuous.
- Other: Surge suppression.
Indicators (LED)
- Input: 24VDC is present.
- Output: Powered.
Input
- Voltage: 24VDC from eFlow4NB.
- Fusing: 10A / 250V.
Output
- Voltage: 24VDC.
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
- b) Four (4) dry form “C” 5A rated relay outputs.
- c) Any combination of the above.
- Four (4) auxiliary power outputs (unswitched).
Outputs Ratings
- Fuses: 3A / 32VDC.
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized).
- Green LED: FACP disconnect is triggered.
Input
- Voltage: 12VDC from VR6 and 24VDC from eFlow4NB.
- Main Fuse Rating: 10A.
Output
- Voltage: 12VDC and/or 24VDC.
- Any of the eight (8) fuse protected power outputs are selectable to follow power Input 1 or Input 2.
- Individual outputs may be set to OFF position for servicing.
Outputs Ratings
- Fuses: 3A / 250V.
Indicators (LED)
- DC Output: Eight (8) individual output LEDs.
- Control up to 2 gates or doors
- 500 four-digit access-code capacity
- "3 strikes, you’re out" security
- Personal master code
- Latch code and sleep code
- One-time-use code
- Non-volatile memory
- Variable relay time
- Event input
- Audible tones and LED feedback
- Nightlight
- Faceplate
- Ascent Camera
- 511 and 512 circuit boards
- 4G LTE antenna
- PS-12DC1 power supply
Input
- Voltage: 120VAC, 60Hz.
- Fusing: 5A / 250V.
Output
- Voltage: 24VDC.
- Current: 4A continuous.
- Other: Overvoltage protection. Filtered and regulated.
- Capacity: 7AH / 12VDC (Up to 2 within enclosure). 40 AH / 65 AH (requires separate enclosure).
- Type: Sealed lead acid or gel type.
- Fuse: Rating 10A/32V.
- Failover: Upon AC loss, instantaneous.
- AC Failure: Form “C” contacts.
- Battery: Form “C” contacts.
- Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units (depending on the power supply). Prevents deep battery discharge.
- Input: 120VAC is present.
- DC Output: Powered.
- Battery: Discharged or not connected.
Input
- Voltage: 24VDC from eFlow4NB.
Output
- Voltage: 12VDC.
- Current: 6A continuous.
- Other: Surge suppression.
Indicators (LED)
- Input: 24VDC is present.
- Output: Powered.
Input
- Voltage: 24VDC from eFlow4NB.
- Fusing: 10A / 250V.
Output
- Voltage: 24VDC.
- Four (4) independently controlled 2.5A outputs:
- a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
- b) Any combination of the above.
- Four (4) auxiliary power outputs (unswitched).
Outputs Ratings
- PTCs: 2.5A.
Indicators (LED)
- Red LEDs: Outputs are triggered (relays energized).
- Green LED: FACP disconnect is triggered.
- Voltage: 12VDC from VR6 and 24VDC from eFlow4NB.
- Main Fuse Rating: 10A.
Output
- Voltage: 12VDC and/or 24VDC.
- Any of the eight (8) power outputs are selectable to follow power Input 1 or Input 2.
- Individual outputs may be set to OFF position for servicing.
Outputs Ratings
- PTCs: 2A.
Indicators (LED)
- DC Output: Eight (8) individual output LEDs.