Altronix AL1024ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 10A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.

Item#:
AL1024ULACM
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Compatible w/ KT-200 door controller but requires 12 VDC power supply

Item#:
KT-MOD-REL8
You must be logged in to order this item. Log in here

Altronix ACM8CB converts one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2.5A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM8CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Item#:
ACM8CB
You must be logged in to order this item. Log in here
The MD-D02B is a plug-in expansion module for Rosslare’s AC-225x-B access control panels that provides a 2-reader interface, 4 supervised inputs with end-of-line (EOL) resistor protection, and 4 relay outputs (5 Amp Form-C N.O./N.C.) to the panel. Installation of the module takes under one minute with the tailored expansion port in the panels and auto-recognize by the panel. Once it is installed and the panel is powered on, the expansion is recognized by the AxTraxNG server, and the MD-D02B can be programmed for access control and automation. Advanced communication with the controller allows for firmware update and real-time event logging, with support for full offline operation by the host panel.
  • Additional two proximity readers or keypads
  • Four relay outputs and four supervised inputs to the access control panel
  • Wiegand or Clock-and-Data transmission keypad or biometric reader compatibility
  • LED status feedback for 12 V power and relay activation
  • Cost effective and modular installation
  • Input and output configurability using Rosslare’s AxTraxNG™ software
Item#:
MD-D02B
You must be logged in to order this item. Log in here

The EM-Mag1500 compact electromechanical lock is designed for outswinging doors and small enclosures. The RCI EM-Mag1500 is significantly smaller than standard electromagnetic locks. This electromechanical solution includes a bi-color light panel for indicating lock status, an early warning alarm, and an anti-tamper security plate.

  • Energy: 240mA Field-Selectable 12/24VDC (At 12VDC, 120mA at 24VDC)
  • Strength: 1,500lbf Holding Force
  • Mode: Fail-Safe
  • Monitor: Lock & Door Status Sensors
  • Warranty: 3 Year Limited Warranty

Item#:
EM-MAG1500
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix AL600ULACMCB converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 6A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
  • Short circuit and thermal overload protection.
  • AC fail supervision (form "C" contact).

Item#:
AL600ULACMCB
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • Side Printing: Single or dual
  • Print Method: Dye-sublimation / resin thermal transfer
  • Resolution: 300 dpi
  • Print Speed: 16 seconds per card / 225 cards per hour (YMCKO)
  • Included Software: Embedded Swift ID® badging application and FARGO Workbench printer maintenance and diagnostic software with Color Assist spot-color matching
  • Data protection: AES-256 encryption on the printer over a secure network
  • Card capacity: 200 card input (with dual input hopper), 100 card output
Accepted Card Sizes:
  • CR-80
  • CR-79 Adhesive Back

Item#:
HID55100
You must be logged in to order this item. Log in here

  • Large 2 in. square illuminated button mounted on stainless steel faceplate
  • Heavy duty stainless steel faceplate
  • CM-30EE: 30 second fixed timer
  • In-wall back box included
  • 12/24V with LED bulb
  • Tamper proof screws and driver included
  • Double break design for additional security