The SK-MONITOR-2 is an addressable monitor module with two initiating circuits that act as an interface to dry contact devices such as waterflow switches and conventional pull stations.
Features
- Connect up to 17 panels with convenient single point visability. Copper wire or fiber optic cable panel connectivity can be used within the same linked system. Compatible FACPs can be linked within one system
- Built-in dual path IP and POTs communication for reliable dual path backup
- Built-in USB interface for convenient and speedy programming
- SWIFT® capable for wireless detection -- perfect for hard-to-wire installs
- Field-upgradeable firmware saves time and money - no need to return panels for updates
- Supports up to 12 remote annunciators for convenient and efficient system status reporting
- Large easy-use keypad and 4 x 20 - 80 character display
- Includes access to Jumpstart™, HFSS programming software and the SKST selection tool
- NAC Circuits: 4; 6 amps power supply
- Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuit
The SK-ZONE-6 is addressable six circuit zone module that allows an IntelliKnight fire alarm controls to interface and monitor two-wire conventional smoke detectors.
Features
- Fiber solution allows one fire alarm control panel to protect multi-building applications eliminating the monitoring costs of multiple phone lines
- Eliminates the risk of lightning damage caused by running copper wire between buildings
- SK-F485C does not take up an SBUS address and allows for long distance location of SBUS accessories
- Multi-mode fiber distance up to 1 mile depending on db fiber rating
- UL listed
The SK-RELAY is an addressable relay module that allows an IntelliKnight fire alarm control to switch discrete contacts by code command. The module contains two isolated sets of Form C contacts.
Features
The SK-CONTROL is an addressable notification module and provides supervised monitoring of wiring to the load devices that require an external power supply to operate such as bells, horns, and strobes.
Features
Fire-Lite's MMF-300-10(A) ten-input monitor module provides an interface between the MS-9050UD, MS-9200UDLS, and MS-9600(UD)LS and normally open contact devices such as pull stations, security contacts or flow switches. Provisions are included for disabling a maximum of two unused addresses.
Features
Addressable Fire Alarm Control with Upload/Download, 636-Points
Addressable Fire Alarm Control with Upload/Download, 636 Points on Two Signaling Line Circuit's (SLC's), with built in Dialer, (2nd SLC Optional, 24VDC
MS-9600LS is a 318-point addressable fire alarm control panel with optional Digital Alarm Communicator/Transmitter (DACT-UD2) and expandable to 636 addressable points with an optional second Signaling Line Circuit (SLC-2LS).
- Up to 159 detectors and 159 control/monitor modules (total of 318 devices) per SLC (636 with SLC-2LS option card)
- Uses PS-Tools programming utility
- LiteSpeed protocol for SLC communication polls 10 devices at a time and operates on standard, unshielded wire
- Auto programmable function reduces installation time
- Advanced Fire Technology includes sensitivity testing and automatic drift compensation
- 7 amps of power distributed across 4 NAC circuits with onboard Sync Select for System Sensor, Gentex , or Wheelock devices