|◀ 13 - 24 of 85 ▶|
View:

The CRF-300 Addressable Relay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeed is a communication protocol developed by FireLite Engineering that greatly enhances the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs.

Features

  • Built-in type identification automatically identifies these devices to the control panel.
  • Internal circuitry and relay powered directly by two-wire SLC loop.
  • Integral LED blinks green each time a communication is received from the control panel and turns on in steady red when activated.
  • High noise immunity (EMF/RFI).
  • Wide viewing angle of LED.
  • SEMS screws with clamping plates for wiring ease.
  • Direct-dial entry of address: 01 159 for MS-9600(A) series
Item#:
CRF-300
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The CMF-300 Addressable Control Module provides FireLite intelligent control panels a circuit for Notification Appliances (horns, strobes, etc.). Addressability allows the CMF-300 to be activated through panel programming, on a select (zone or area of coverage) basis. LiteSpeed is a communication protocol developed by FireLite Engineering that greatly enhances the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs.

Features

  • Built-in type identification automatically identifies these devices to the control panel.
  • Internal circuitry powered directly by two-wire SLC loop. The CMF-300 module requires power (for horns, strobes, etc.).
  • Integral LED blinks green each time a communication is received from the control panel and turns on steady red when activated.
  • High noise immunity (EMF/RFI).
  • The CMF-300 may be used to switch 24-volt NAC power.
  • Wide viewing angle of LED.
  • SEMS screws with clamping plates for wiring ease.
  • Direct-dial entry of address: 01 159 for MS-9600 series panels, 01  99 on MS-9200UDLS and MS-9050UD.

Item#:
CMF-300
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
The Endurance Series ES-50X is a 50-point addressable fire alarm control panel that offers built-in dual path communications, programmable buttons and support for combined fire and CO addressable detection.
  • Upload/Download panel programming database and flash firmware with USB thumb drive
  • Addressable multi-criteria detector (smoke, heat, CO) with programmable response
  • Addressable Sounder Bases
  • Four programmable function keys
  • Built in Class-A capability for all 2 NACs; no optional card required
  • Trouble indication for SLC devices not programmed
  • Automatic discovery of "relay" versus "NAC" type control modules during auto-programming of SLC loop
  • Integrated SWIFT display driver and annunciator built-in to panel
Item#:
ES-50X
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Maximum 1,110 point addressable fire alarm control panel. Includes connected panel options, enhanced communications, wireless detection and other advanced features. (Replaces the 5820XL).
  • Connect up to 17 panels with convenient single point communications. Copper wire or fiber optic cable panel connectivity can be used within the same linked system
  • Multiple Signal Line Circuits (SLCs) can be used within one system limited only by maximum points available
  • Built-in dual path IP and POTs communication for reliable dual path backup
  • Built-in USB interface for convenient and speedy programming
  • SWIFT® capable for wireless detection
  • Convenient field-upgradeable firmware
  • Supports up to 16 remote annunciators
  • Programmable date setting for automatic and convenient Daylight Saving Time changes
  • 4 x 20 annunciator with 80 character display and large easy-use keypad
  • Includes access to Jumpstart™, HFSS programming software and the SKST selection tool
  • NAC Circuits: 6; 6 amps power supply
  • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuit
Item#:
006820
You must be logged in to order this item. Log in here
  • New modern profile for improved aesthetics
  • Stable communication technique with noise immunity
  • Low standby current
  • Two-wire SLC connection
  • Optional remote, single- gang LED accessory
  • Dual LED design provides 360° viewing angle
  • Remote test feature from the panel
  • Built-in functional test switch activated by external magnet
  • Built-in tamperresistant feature
  • Sealed against back pressure
  • Expanded color options
  • SEMS screws for wiring of the separate base
  • Optional relay, isolator, and sounder bases
  • Plugs into separate base for ease of installation and maintenance
Item#:
SK-PHOTO-W
You must be logged in to order this item. Log in here

The SK-MONITOR-2 is an addressable monitor module with two initiating circuits that act as an interface to dry contact devices such as waterflow switches and conventional pull stations.

Features

  • Monitor two circuits with unique addresses simultaneously
  • Rotary address switches for fast installation
  • Support for Class B wiring
  • Bright white cover plate
  • SEMS screws for easy wiring
  • UL listed

Item#:
SK-MONITOR-2
You must be logged in to order this item. Log in here
Maximum 198 point single loop addressable fire alarm control panel. Includes connected panel options, enhanced communications, wireless detection and other advanced features. (Replaces the 5808)
  • Connect up to 17 panels with convenient single point visability. Copper wire or fiber optic cable panel connectivity can be used within the same linked system. Compatible FACPs can be linked within one system
  • Built-in dual path IP and POTs communication for reliable dual path backup
  • Built-in USB interface for convenient and speedy programming
  • SWIFT® capable for wireless detection -- perfect for hard-to-wire installs
  • Field-upgradeable firmware saves time and money - no need to return panels for updates
  • Supports up to 12 remote annunciators for convenient and efficient system status reporting
  • Large easy-use keypad and 4 x 20 - 80 character display
  • Includes access to Jumpstart™, HFSS programming software and the SKST selection tool
  • NAC Circuits: 4; 6 amps power supply
  • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuit
Item#:
006808
You must be logged in to order this item. Log in here

The SK-ZONE-6 is addressable six circuit zone module that allows an IntelliKnight fire alarm controls to interface and monitor two-wire conventional smoke detectors.

Features

  • Converts a conventional two-wire loop to an address on the SLC loop
  • Six zone inputs
  • Rotary address switches for fast installation
  • Support for Class B and Class A wiring
  • Individual LED for each zone circuit
  • Up to two unused circuits can be disabled
  • UL listed

Item#:
SK-ZONE-6
You must be logged in to order this item. Log in here

The SK-MONITOR is an addressable monitor module that acts as an interface to dry contact devices such as waterflow switches and conventional pull stations.

Features

  • Single contact monitor
  • Rotary address switches for fast installation
  • Support for Class B or Class A wiring
  • Bright white cover plate
  • SEMS screws for easy wiring
  • UL listed
Item#:
SK-MONITOR
You must be logged in to order this item. Log in here
|◀ 13 - 24 of 85 ▶|