Home  >  FIRE  > (x)
|◀ 37 - 48 of 7433 ▶|
View:

  • Back box or side mount with mounting tabs
  • Lens made of Clear Lexan®
  • Reinforcement steel hardware
  • Textured plastic finish
  • Weatherproof seal
Item#:
GOE-R
You must be logged in to order this item. Log in here

Supervises up to 5 remote microphones

Item#:
EVX-SC
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • Circuit breaker lockout tab
  • Hex key
  • Panel identification stickers
Item#:
ELOCK-FA
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix AL400ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4A @ 12VDC or 3A @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.

Item#:
AL400ULACM
You must be logged in to order this item. Log in here
Item#:
B200SR-LF-WH
You must be logged in to order this item. Log in here
Item#:
ELR-47K
You must be logged in to order this item. Log in here
Features
• Photoelectric, integrated low-flow technology
• Air velocity rating from 100 ft/min – 4,000 ft/min (0.5 m/s – 20.32 m/s)
• Versatile mounting options: square or rectangular configuration
• Broad ranges for operating temperature (-4°F – 158°F, -20°C – 70°C) and humidity (0% – 93% non-condensing)
• Sampling tube installs from front or back of the detector with no tools required
• Cover tamper signal
• Increased wiring space with a newly added 3/4" conduit knockout
• Easily accessible code wheels on sensor head (Included with D365PL/D365PLA)
• Clear cover for convenient visual inspection (D365PL(A) only)
• Remote testing capability
• Requires com line power only
• Housing accommodates an addressable relay module, sold separately, (CRF-300) for applications requiring a Form-C relay
Item#:
D365PL
You must be logged in to order this item. Log in here

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL802ULADA
You must be logged in to order this item. Log in here

  • Each unit includes four onboard fully supervised audio circuits which are expandable to eight circuits when an ECC-CE4 module is added
  • Any combination of up to eight ECC-50DAs or ECC-125DAs per system for a total of 1100 watts of audio power and 24 speaker circuit outputs.
  • Supports both Class A (Style Z) and Class B (Style Y) wiring.
  • Easy setup and configuration by using a simple, built-in web based programming utility on the ECC-50/100
  • UL2572 (Communication and Control Units Mass Notification Systems).
  • Built-in power supply and battery charger that supports up to 35AH. (For batteries larger than 18 AH, use the BB-26 or BB-55F Battery Box.)
  • ECC-50DA is field selectable for 25 volts or 70.7 volts of operation.
  • Sturdy, scratch resistant cabinet.
Item#:
ECC-50DA
You must be logged in to order this item. Log in here
|◀ 37 - 48 of 7433 ▶|
View:
(Denotes required field.)