Connection and mounting is simplified using the enclosure kit.
Item#:
HW-AV-ENC
You must be logged in to order this item. Log in here

Provides Connections for up to Six Style Z (Class A) or Style Y

Item#:
ECC-CE6
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Remote 4-output NAC Extender, for 6.5A ttl, or 2A, max. on any 1 output. Red 14 x 16" can, connects to 120VAC, supports 24V 16Ah standby batts.  Supervised, fire bus connection. System Sensor and Wheelock NAC sync. (5/system, for 20 add’l NAC circuits ttl.). 3 Programmable relay outputs;  2 low voltage; 1 high-voltage 120V rated relay.
Item#:
GEMC-NAC7S
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix AL400ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4A @ 12VDC or 3A @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.

Item#:
AL400ULACM
You must be logged in to order this item. Log in here
Item#:
B200SR-LF-WH
You must be logged in to order this item. Log in here
Item#:
ELR-47K
You must be logged in to order this item. Log in here
Features
• Photoelectric, integrated low-flow technology
• Air velocity rating from 100 ft/min – 4,000 ft/min (0.5 m/s – 20.32 m/s)
• Versatile mounting options: square or rectangular configuration
• Broad ranges for operating temperature (-4°F – 158°F, -20°C – 70°C) and humidity (0% – 93% non-condensing)
• Sampling tube installs from front or back of the detector with no tools required
• Cover tamper signal
• Increased wiring space with a newly added 3/4" conduit knockout
• Easily accessible code wheels on sensor head (Included with D365PL/D365PLA)
• Clear cover for convenient visual inspection (D365PL(A) only)
• Remote testing capability
• Requires com line power only
• Housing accommodates an addressable relay module, sold separately, (CRF-300) for applications requiring a Form-C relay
Item#:
D365PL
You must be logged in to order this item. Log in here