ActionsConnection and mounting is simplified using the enclosure kit.
Item#:
HW-AV-ENC
You must be logged in to order this item.
Log in here
Provides Connections for up to Six Style Z (Class A) or Style Y
Item#:
ECC-CE6
You must be logged in to order this item.
Log in here
Item#:
BB-55F
You must be logged in to order this item.
Log in here
Remote 4-output NAC Extender, for 6.5A ttl, or 2A, max. on any 1 output. Red 14 x 16" can, connects to 120VAC, supports 24V 16Ah standby batts. Supervised, fire bus connection. System Sensor and Wheelock NAC sync. (5/system, for 20 add’l NAC circuits ttl.). 3 Programmable relay outputs; 2 low voltage; 1 high-voltage 120V rated relay.
Item#:
GEMC-NAC7S
You must be logged in to order this item.
Log in here
Item#:
FWC-FSLC-PROG2
You must be logged in to order this item.
Log in here
Item#:
DST10
You must be logged in to order this item.
Log in here
The CO-REPL makes it easy and affordable to replace an end-of-life CO cell on an i4 Series detector without having to replace the entire unit.
COSMO-2W and COSMO-4W detectors are equipped with a feature that will signal the fire alarm control panel once the CO sensor has passed the end of its’ useful life. This signal indicates that the CO sensor inside the detector must be replaced with the CO-REPL. If left unresolved for 30 days, the detector will chirp intermittently.
The typical lifespan of the CO-REPL is ten years from the date of manufacture. There is also a “Replace By” sticker located on the CO cell that will indicate the date which the CO cell should be replaced.
Item#:
CO-REPL
You must be logged in to order this item.
Log in here
- CO1209 Series is 120VAC with 9V battery back-up
- Low or missing battery indicator
- 9V battery shipped with product
- Electrochemical sensor
- Push button self test feature
- Push button functional test
- Horn frequency 3100Hz (Nominal)
- Temporal 4 sounding pattern for CO annunciation
- Dualink® – tandem interconnect with all Gentex tandem capable alarms
- CO1209F features one (1) set of Form A/Form C relay contacts
- Quick disconnect wiring harness
- Non-latching (self restoring)
- End of life signal indicating CO sensor has reached depletion state
- Mounting hardware adapts to standard junction boxes
Item#:
CO1209F
You must be logged in to order this item.
Log in here
Item#:
DCD-1E-IS
You must be logged in to order this item.
Log in here
Converts the ECC-50/100 primary amplifier to a 70V
Item#:
ECC-XRM-70V
You must be logged in to order this item.
Log in here
The ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels that may be used for fire applications, mass notification applications or both. These state-of the-art Primary Operator Consoles (POCs) are capable of producing either 50 or 100 watts of audio power that can be distributed to up to eight speaker circuits (i.e., zones).
Features
- UL Listed to UL2572 Communication (Control Units Mass Notification Systems).
- Modular design for maximum system flexibility and easy expansion.
- 50 watts of 25 V audio power (expandable to 100 watts) RMS.
- Optional amplifier can be configured as a backup in the event the primary amplifier fails. Amplifiers are independently powered to eliminate system interruption during a short circuit condition
- Eight Command Input Circuits to activate messages 1 to 8:
- Seamless integration and control when connected to select Fire-Lite panels through the ANN/ACS (EIA-485) communication bus.
- Speaker circuits are expandable by up to 8 outputs (With an optional circuit expander module).
- Removable terminal blocks for ease of servicing and module replacement.
- 2 amp Notification Appliance Circuit (NAC) output, sync generator, or follower for System Sensor, Wheelock or Gentex protocols:
- Integral supervised microphone.
- 520HZ square wave tones can be uploaded to ECC-50/100 to meet NFPA Low Frequency requirements
Item#:
ECC-50/100
You must be logged in to order this item.
Log in here