  • Single device for CO and smoke detection that uses less wiring and fewer junction boxes
  • Compatible with a wide range of control panels with the use of the required i4 Interface Module.
  • Sends distinct smoke and CO signals to the panel
  • Sounds Temporal 3 for smoke and Temporal 4 for CO
  • Built-in 85dB sounder
  • LEDs display both CO and smoke status
  • External IR LED provides extended range sensitivity testing
  • Versatile mounting allows for wall or ceiling placement
  • Easily replaceable electrochemical CO cell with 10-year end-of-life timer that signals the panel and chirps to alert the homeowner
  • RealTest® enables functional test using canned CO
  • Drift compensation and smoothing algorithms provide false alarm immunity
  • Compatible with SENS-RDR sensitivity tester
  • Full agency compliance with UL 268 and UL 2075
Item#:
COSMO-2W
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

CLSS PATHWAY - FIRE ALARM COMM UNICATOR, LTE, DUAL SIM

This item has been discontinued and replaced by item 
Hardware Features:
• Dual SIM automatically picks from AT&T or Verizon networks for ultimate redundancy and reliability
• LTE-CAT-M1 network is 5G-ready for deep signal penetration inside buildings
• Meets UL 864 requirements for sole, primary or backup path communications
• Universal fire alarm control panel (FACP) compatibility and direct power from 24 volt FACP
• Introductory offer includes first year of cellular/IP service included in purchase price
• Enclosure kit sold separately (HW-AV-ENC)
Software Features:
• CLSS Site Manager provides a “bird’s eye” view of all your accounts and real-time information on event generation so you can diagnose before dispatch. Reduce unnecessary trips & improve your first-time fix rate.
• CLSS Facility Manager provides your end users with event alerts via browser or mobile app and access to asset information across multiple sites.
• CLSS CheckPoint allows you to deliver professional test reports before leaving your customer’s site.

Item#:
HW-AV-LTE-M
You must be logged in to order this item. Log in here

The BG-12 series from Fire-Lite Alarms is a cost-effective, feature-packed, non-coded series of manual fire alarm pull stations. They offer a variety of different models including single- and dual-action versions. The BG-12 series were designed specifically for use in multiple applications and offer the flexibility to meet the needs of both the installer and end-user.

Item#:
BG-12L
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time during system commissioning.

Features

  • Listed to UL Standard 864, 9th Edition.
  • Backlit 80-character LCD display (20 characters x 4 lines).
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset.
  • Control switches can be independently enabled or disabled at the FACP.
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Keyswitch can be enabled or disabled at the FACP.
  • Enclosure supervised for tamper.
  • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence.
  • Local sounder can be enabled or disabled at the FACP.
  • ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming.
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels.
  • Time-and date display field.
  • Surface mount directly to wall or to single, double, or 4in. square electrical box.
  • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting.
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel.
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs.
  • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC).
  • Up to eight ANN-80s can be connected on the ANN-BUS