The 5895XL intelligent power module is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with Silent Knight addressable fire alarm control panels. Six Flexput circuits can be programmed as notification appliance circuits, conventional initiation circuit, or auxiliary power for constant, resettable or door holder power. The 5895XL also provides a conditioned SBUS circuit allowing up to an additional 6,000 feet of wiring for SBUS devices.
Features
- 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
- Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
- Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
- Compatible with 12VDC or 24VDC fire panels.
- Output loop supervision steered to input 1 or input 2.
- Signal circuit trouble memory (helps identify intermittent loop problems).
- Common trouble input and output.
- Ground fault detection.
- Unit includes power supply, red enclosure, cam lock, and battery leads.
The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time during system commissioning.
Features
Fire Alarm Control Panel, 4-Zone, Class B/A (Use CAC-4 for ClassA), 24VDC, 1 Classs B/A (Use CAC-4 for Class A) NAC
MS-4 is a four zone conventional fire alarm control panel compatible with the new I3 smoke detectors from System Sensor, and provides such advanced features as drift compensation, maintenance alert, and freeze warning. Automatic synchronization of audio/visual devices is provided, using manufacturer protocol for System Sensor, Wheelock and Gentex appliances. The NAC protocol includes the ability to silence audible devices while strobes continue to flash, using only a single pair of wires.
Features