Features
• Photoelectric, integrated low-flow technology
• Air velocity rating from 100 ft/min – 4,000 ft/min (0.5 m/s – 20.32 m/s)
• Versatile mounting options: square or rectangular configuration
• Broad ranges for operating temperature (-4°F – 158°F, -20°C – 70°C) and humidity (0% – 93% non-condensing)
• Sampling tube installs from front or back of the detector with no tools required
• Cover tamper signal
• Increased wiring space with a newly added 3/4" conduit knockout
• Easily accessible code wheels on sensor head (Included with D365PL/D365PLA)
• Clear cover for convenient visual inspection (D365PL(A) only)
• Remote testing capability
• Requires com line power only
• Housing accommodates an addressable relay module, sold separately, (CRF-300) for applications requiring a Form-C relay
Item#:
D365PL
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision directed to input 1 or input 2.
  • Signal Circuit Trouble Memory - facilitates quick identification of an intermittent/fault (short circuit, open or ground) which has previously occurred on one or more signaling circuit outputs. LEDs indicate/identify which output the fault has occurred.
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, logic board enclosure, cam lock, and battery leads.
Item#:
AL1042ULADA
You must be logged in to order this item. Log in here
Item#:
ESB-KIT-W
You must be logged in to order this item. Log in here
The CO-REPL makes it easy and affordable to replace an end-of-life CO cell on an i4 Series detector without having to replace the entire unit.
COSMO-2W and COSMO-4W detectors are equipped with a feature that will signal the fire alarm control panel once the CO sensor has passed the end of its’ useful life. This signal indicates that the CO sensor inside the detector must be replaced with the CO-REPL. If left unresolved for 30 days, the detector will chirp intermittently.
The typical lifespan of the CO-REPL is ten years from the date of manufacture. There is also a “Replace By” sticker located on the CO cell that will indicate the date which the CO cell should be replaced.
Item#:
CO-REPL
You must be logged in to order this item. Log in here
Item#:
ESB-KIT-R
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Increases the total EC-50/100 Power output to 100W

Item#:
ECC-50W-70V
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
|◀ 1 - 12 of 5516 ▶|
View:
(Denotes required field.)