4-Door Access Control Starter Kit. Includes: EntraPass Corporate Edition Software USB Key, KT-400 Controller, 3 P225XSF Readers, 1 P225KPXSF Reader, USB-485 Communication Interface, TR1675 16 VAC/75 VA Transformer, KT-BATT-12 12V 7 AH Battery & 5 P40KEY Keyfobs

Item#:
SK-CE402
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Altronix T1RV3F4 rack kit is pre-assembled and consists of Trove1M1R enclosure/backplane with factory installed Altronix power supply/charger and sub-assemblies. This kit also accommodates various combinations of HID VertX® boards for up to six (6) doors in a single enclosure.
Power Supply (eFlow6NB):
Input
  • Voltage: 120VAC, 60Hz, 3.5A max.
  • Fusing: 5A / 250V.
Output
  • Voltage: Factory set at 24VDC.
  • Current: 6A continuous.
  • Maximum Supply Current for Main and Aux. Outputs on eFlow6NB Power Supply board, PDS8 Power Distribution Module’s and ACM4 Access Power Controller’s outputs is 5.6A.
  • Auxiliary: Class 2 power-limited @ 1A (unswitched).
  • Other: Overvoltage protection. Filtered and regulated.
Battery Backup
  • Built-in charger for sealed lead acid or gel type batteries (if batteries are required, install separate battery enclosure RE2).
  • Automatic switch over to stand-by battery when AC fails.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
Fire Alarm Disconnect
  • Supervised: Latching or non latching.
  • EOL: 10K Resistor.
Supervision
  • AC Failure: Form “C” contacts.
  • Battery: Form “C” contacts.
  • Low DC Power Shutdown: Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge.
Indicators LED
  • Input: 120VAC is present.
  • DC Output: Powered.
  • Battery: Discharged or not connected.
Access Power Controller (ACM4):
Input
  • Voltage: 24VDC from eFlow6NB.
  • Fusing: 10A / 250V.
Output
  • Voltage: 24VDC.
  • Four (4) independently controlled 2.5A outputs:
  • a) Four (4) Fail-Safe and/or Fail-Secure power outputs.
  • b) Four (4) dry form “C” 5A rated relay outputs.
  • c) Any combination of the above.
  • Four (4) auxiliary power outputs (unswitched).
  • Fuses Rating: 3A / 32VDC.
Indicators (LED)
  • Red LEDs: Outputs are triggered (relays energized).
  • Blue LED: FACP disconnect is triggered.
Power Distribution Module (PDS8):
Input
  • Voltage: 24VDC from eFlow6NB and 12VDC from VR6.
  • Fusing: 10A / 250V.
Output
  • Voltage: 12 or 24VDC individually selectable.
  • Fuses Rating: 3A / 32VDC.
Indicators (LED)
  • DC Output: Eight (8) individual output LEDs.
Item#:
T1RV3F4
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here