Features

  • 1, 4 or 8 polyswitch (PTC) 2A circuit breakers based on model
  • LEDs monitor zone status (voltage, no voltage)
  • Slide switches connect or disconnect load from power (excludes 1 Amp)
  • Sealed lead acid-gel battery charging capability (battery not included)
  • Rugged steel enclosure
  • Provided with terminals for fire alarm relay connection, allowing release of all devices upon fire alarm activation
  • Clean linear power for flawless operation with all sensitive active electronic components
  • BPS UL Listed
  • MagnaCare lifetime replacement, no fault warranty

Item#:
BPS-12-6
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix ACM4E converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form C contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4E will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Item#:
ACM4E
You must be logged in to order this item. Log in here

AL1024ULX is a power supply/charger that converts a 115VAC, 60Hz input into a single 24VDC non-power limited output.

Input

  • Input 115VAC, 60Hz, 4.2A.
  • Input fuse rated @ 3.5A/250V.
Output
  • 24VDC output.
  • 10A of continuous supply current for Access Control applications.
  • 8A of continuous supply current for Fire Alarm applications.
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.

Item#:
AL1024ULX
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here