AL600ULX is a power supply/charger which converts a 115VAC/60Hz input into a single 12VDC or 24VDC non power-limited output.

Input

  • Input 115VAC, 60Hz, 3.5A.
Output
  • 12VDC or 24VDC selectable output.
  • 6A continuous supply current.
  • Filtered and electronically regulated output.
  • Short circuit and thermal overload protection.

Item#:
AL600ULX
You must be logged in to order this item. Log in here

Altronix AL1024ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 10A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.

Item#:
AL1024ULACM
You must be logged in to order this item. Log in here

Altronix ACM8CB converts one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2.5A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM8CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Item#:
ACM8CB
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix ACM4CB converts one (1) 12 to 24 volt AC or DC input into four (4) independently controlled Class 2 rated PTC protected power-limited auto-resettable outputs rated at 2A each. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The ACM4CB will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Item#:
ACM4CB
You must be logged in to order this item. Log in here

Altronix ACM4 converts one (1) 12 to 24 VAC or VDC input into four (4) independently controlled fuse protected outputs. These power outputs can be converted to dry form C contacts. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. ACM4 will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the four (4) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the four (4) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • FACP output relay (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Removable terminal blocks facilitate ease of installation.

Item#:
ACM4
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

Altronix AL600ULACMCB converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 6A continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    Fire Alarm disconnect input options:
    • a) Normally open (NO) or normally closed (NC) dry contact input.
    • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC).
  • Short circuit and thermal overload protection.
  • AC fail supervision (form "C" contact).

Item#:
AL600ULACMCB
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here