Features
• Photoelectric, integrated low-flow technology
• Air velocity rating from 100 ft/min – 4,000 ft/min (0.5 m/s – 20.32 m/s)
• Versatile mounting options: square or rectangular configuration
• Broad ranges for operating temperature (-4°F – 158°F, -20°C – 70°C) and humidity (0% – 93% non-condensing)
• Sampling tube installs from front or back of the detector with no tools required
• Cover tamper signal
• Increased wiring space with a newly added 3/4" conduit knockout
• Easily accessible code wheels on sensor head (Included with D365PL/D365PLA)
• Clear cover for convenient visual inspection (D365PL(A) only)
• Remote testing capability
• Requires com line power only
• Housing accommodates an addressable relay module, sold separately, (CRF-300) for applications requiring a Form-C relay
You must be logged in to order this item. Log in here
Extension bar for the SECO-LARM DH-171SQ Flush-mount Magnetic Door Holder and DH-151SQ Surface-mount Magnetic Door Holder. 
Item#:
DH-100E-10SQ
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The IQ Smoke is connected to your IQ Panel and monitored 24-7, whether your system is armed or not. The IQ Smoke detects the presence of smoke using photoelectric smoke-sensing technology and conforms to UL 217. The IQ Smoke detects the presence of smoke particles as well as the rapid rise in heat that can come from a fire, even if there is no smoke. Because your system is always connected, you can receive a text or email alert if there are any problems, wherever you are.

  • "Always on" technology ensures the sensor is monitored around the clock, whether your system is armed or not
  • Ultra sensitive smoke sensor prevents false alarms while constantly monitoring
  • Heat sensor detects the rapid rise in heat that comes from a fire - even when there is no smoke (like an electrical fire)
  • Wall or ceiling mounted
  • 3-5 year battery life


Item#:
QS5110-840
You must be logged in to order this item. Log in here
Item#:
ESB-KIT-W
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The LCD-80F is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the FireLite MS9200UD Series and MS-9600 Series Fire Alarm Control Panels (FACPs). The LCD-80F displays complete system point status information and includes control switches for remote control of critical system functions.

Up to 32 LCD-80Fs may be connected onto the EIA-485 terminal port of each FACP. The LCD-80F requires no programming, which saves time during system commissioning.

Features

  • 80-character Liquid Crystal Display.
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key.
  • System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced.
  • No programming necessary  LCD-80F connects to the terminal port (TB7)
  • Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels.
  • Time-and-date display field.
  • Aesthetically pleasing design.
  • May be powered from the host FACP or by remote power supply (requires 24 VDC).
  • Up to 32 LCD-80F annunciators per FACP.
  • Plug-in terminal blocks for ease of installation and service

Item#:
LCD-80F
You must be logged in to order this item. Log in here
The CO-REPL makes it easy and affordable to replace an end-of-life CO cell on an i4 Series detector without having to replace the entire unit.
COSMO-2W and COSMO-4W detectors are equipped with a feature that will signal the fire alarm control panel once the CO sensor has passed the end of its’ useful life. This signal indicates that the CO sensor inside the detector must be replaced with the CO-REPL. If left unresolved for 30 days, the detector will chirp intermittently.
The typical lifespan of the CO-REPL is ten years from the date of manufacture. There is also a “Replace By” sticker located on the CO cell that will indicate the date which the CO cell should be replaced.
Item#:
CO-REPL
You must be logged in to order this item. Log in here