  • High quality, low profile, low frequency audible and visible appliance
  • Produces a 520 Hz square wave, temporal 3 tone
  • Fixed candela options: 15, 110, and 177
  • Jumper Selection for normal or loud dBA
  • Input terminals accept 12 to 18 AWG
  • Super-Slide Bracket - Ease of Supervision Testing
  • Checkmate - Instant Voltage Verification
  • Temporal 4 pattern available when used with compatible panels
  • Prewire entire system, install mounting bracket, then install signals
  • Silence signal while visual appliance will remain flashing (for use in accepted jurisdictions.
  • Faceplate available in red or off-white
  • Wall mount
  • Five year warranty

Item#:
4890076
You must be logged in to order this item. Log in here

  • Provides Class A connection for NACs & P-Link
  • Exclusive to the PFC-4064 FACP
  • Product includes a 5 year warranty

Item#:
3992361
You must be logged in to order this item. Log in here

  • Industry leading 4 line by 40 Character LCD
  • Common buttons for navigation
  • Common LEDs for status indication
  • 31 annunciator per panel
  • Maximum wire length of 6,500 feet
  • Available in 4 colors
  • Product includes a 5 year warranty
  • UUKL Listed for Smoke Control
Item#:
3992725
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

(Class I, Div. 1), Surf. Mount, 25 or 70 Volt, Red

Item#:
1460235
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • Integrated Sounder in base
  • 75 dB (UL 464 Listed) sounder output
  • Sounder independent of sensor, allows for a single station, grouped or all-call
  • May be mapped to any device connected to the control panel
  • Terminals accept 22 to 12 AWG wire sizes
  • Supports Class A, Class X and Class B wiring
  • Does not require SLC Loop address
  • UUKL Listed for Smoke Control

Item#:
3992729
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • 100 addresses available on this analog addressable system
  • Additional system capacity achieved via multi-point SLC modules
  • 99 software zones
  • NFPA 72 Compliant Smoke Sensitivity Test Built-In
  • System Operates as Class A or Class B for SLC, P-Link and NACs
  • 5 Amp Power Supply, Expandable to 310 amps
  • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
  • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each
  • Strobe Synchronization and System Wide Sync for Gentex, AMSECO, Cooper Wheelock and System Sensor strobes
  • Dedicated Alarm, Supervisory and Trouble Relays
  • 4,000 Event History Buffer
  • Optional two line DACT with UD-1000 that can report General,Zone or Point Information
  • Built in IP Communicator
  • Ethernet Port for Programming and Network Connectivity
  • E-Mail System Status, Reports and Event Information

Item#:
3992753
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • 10 Amp Power Supply
  • 3 Amps, regulated per NAC
  • 6 NACs Class B or 3 NACs Class A
  • 2 dry contact inputs
  • Fully programmable and monitored through control panel
  • Isolated P-Link repeater connection, Class A or B
  • Up to 31 power supplies per control panel with system wide sync
  • Quadrasync feature synchronizes strobes from Potter/AMSECO, Gentex, Cooper-Wheelock and System Sensor.
  • Compatible with all Potter PFC-6000 series fire alarm control panels.

Item#:
3992665
You must be logged in to order this item. Log in here