Compatible with conventional 2-wire smoke detectors IDC can be wired One (1) Class A or Two (2) Class B Monitors presence of 24VDC Aux Power SLC Class A, Class X & Class B Mounts in a standard 4 or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12AWG Product includes a 5 year warranty UUKL Listed for Smoke Control
Single or Dual Action versions Durable die-cast construction Reset key matches the fire alarm control panels Compatible with IPA Series panels SLC Class A, Class X & Class B Product includes a 5 year warranty UUKL Listed for Smoke Control
Allows RS-485 (P-Link) circuit to be converted to/from fiber optic cable Class B or Class A operation Uses 62.5/125 micron multi-mode fiber optic cable; tolerates up to 12 db of signal loss (wave length 820 nm) Mounts with included stacker bracket Mounts in panel, accessory cabinet or PSN-1000/E Power Supply Optional FIB-1000RM 19-inch rack mount model available Maximum of 30 FIB-1000s per panel Product includes a 5 year warranty UUKL Listed for Smoke Control
Monitored output module that provides an additional supervised output Can be used as either a NAC or Releasing Output NAC can be wired Class A or Class B Monitors presence of 24 VDC Aux Power SLC Class A, Class X & Class B Mounts in a standard 4 or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG Product includes a 5 year warranty UUKL Listed for Smoke Control
High quality, low profile, low frequency audible and visible appliance Produces a 520 Hz square wave, temporal 3 tone Fixed candela options: 15, 110, and 177 Jumper Selection for normal or loud dBA Input terminals accept 12 to 18 AWG Super-Slide Bracket - Ease of Supervision Testing Checkmate - Instant Voltage Verification Temporal 4 pattern available when used with compatible panels Prewire entire system, install mounting bracket, then install signals Silence signal while visual appliance will remain flashing (for use in accepted jurisdictions. Faceplate available in red or off-white Wall mount Five year warranty
Single module with dual contact monitoring inputs Two (2) Class B or one (1) Class A monitoring inputs Two (2) Form C relay contacts SLC Class A, Class X & Class B Mounts in a standard 4 or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12 AWG Product includes a 5 year warranty UUKL Listed for Smoke Control
Provides a remotely located Ethernet network connection Fully supervised UL864 compliant Optional 19-inch rack mount available (FCB-1000RM) Maximum 1 FCB-1000 for all compatible Potter fire alarm control panels Maximum P-Link wire length of 6,500 feet Product includes a 5 year warranty UUKL Listed for Smoke Control