|◀ 1 - 12 of 195 ▶|
View:

  • One (1) Form C relay contact
  • SLC Class A, Class X & Class B
  • Mounts in a standard 4 or double gang box
  • Wiring terminals accessible when mounted in box
  • All wiring terminals accept 22 to 12 AWG
  • Product includes a 5 year warranty
  • UUKL Listed for Smoke Control

Item#:
3992705
You must be logged in to order this item. Log in here

  • 50 addresses available on this analog addressable system
  • Additional system capacity achieved via multi-point SLC modules
  • 99 software zones
  • NFPA 72 Compliant Smoke Sensitivity Test Built-In
  • System Operates as Class A or Class B for SLC, P-Link and NACs
  • 5 Amp Power Supply, Expandable to 310 amps
  • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
  • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each
  • Strobe Synchronization and System Wide Sync for Gentex, AMSECO, Cooper Wheelock and System Sensor strobes
  • Dedicated Alarm, Supervisory and Trouble Relays
  • 4,000 Event History Buffer
  • Optional two line DACT with UD-1000 that can report General, Zone or Point Information
  • Built in IP Communicator
  • Ethernet Port for Programming and Network Connectivity
  • E-Mail System Status, Reports and Event Information
  • Product includes 5 year warranty

Item#:
3992752
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS&Y valves ranging in size from 2 to 12 (50mm to 300mm). They will mount on some valves as small as ½ (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device.

Item#:
1010202
You must be logged in to order this item. Log in here

  • Single or Dual Action versions
  • Durable die-cast construction
  • Reset key matches the fire alarm control panels
  • Compatible with IPA Series panels
  • SLC Class A, Class X & Class B
  • Product includes a 5 year warranty
  • UUKL Listed for Smoke Control

Item#:
3992721
You must be logged in to order this item. Log in here

The Model PTS-C is designed to supervise sprinkler system control valves and may also be used to secure gates and other applications. This unit is particularly useful for unusual conditions, such as non-rising stem valves.

Nema 6P enclosure allows the device to be mounted outdoors, even in areas subject to flooding such as pits and wells. Sealed reed switch operation virtually eliminates contact corrosion.

Turning the valve wheel will pull the plug out of the receptacle. The plug cannot be reinserted after operation until the plug receptacle cover is removed with the special hex key provided. This key should be left with the building owner or responsible party. Replacement or additional cover tamper screws and hex keys are available.

Item#:
1010201
You must be logged in to order this item. Log in here

  • One Class B contact monitoring input
  • Small size allows mounting in most electrical boxes
  • SLC Class A, Class X & Class B
  • 6 Pigtail wiring connections
  • Product includes a 5 year warranty
  • UUKL Listed for Smoke Control

Item#:
3992700
You must be logged in to order this item. Log in here

The RTS Series complies with the requirements of NFPA 13 and 72 for a room temperature switch to operate at 40°F to protect a dry pipe valve from freezing. The RTS can also be used for other temperature detection applications.

The normally open detector, RTS-O, will close the contact when the temperature drops below 40°F (4,5°C). The normally closed detector, RTS-C, will open the contact when the temperature drops below 40°F (4,5°C). The detector will automatically reset to the normal state when the temperature rises above 40°F (4,5°C). The RTS Series Room Temperature Sensors are precision engineered, designed and manufactured for commercial or residential use.

Item#:
1010108
You must be logged in to order this item. Log in here

  • 100 addresses available on this analog addressable system
  • Additional system capacity achieved via multi-point SLC modules
  • 99 software zones
  • NFPA 72 Compliant Smoke Sensitivity Test Built-In
  • System Operates as Class A or Class B for SLC, P-Link and NACs
  • 5 Amp Power Supply, Expandable to 310 amps
  • 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188
  • 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each
  • Strobe Synchronization and System Wide Sync for Gentex, AMSECO, Cooper Wheelock and System Sensor strobes
  • Dedicated Alarm, Supervisory and Trouble Relays
  • 4,000 Event History Buffer
  • Optional two line DACT with UD-1000 that can report General,Zone or Point Information
  • Built in IP Communicator
  • Ethernet Port for Programming and Network Connectivity
  • E-Mail System Status, Reports and Event Information

Item#:
3992753
You must be logged in to order this item. Log in here
Item#:
1010117
You must be logged in to order this item. Log in here
Item#:
IDC-6
You must be logged in to order this item. Log in here
|◀ 1 - 12 of 195 ▶|
View: