View:

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time during system commissioning.

Features

  • Listed to UL Standard 864, 9th Edition.
  • Backlit 80-character LCD display (20 characters x 4 lines).
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset.
  • Control switches can be independently enabled or disabled at the FACP.
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Keyswitch can be enabled or disabled at the FACP.
  • Enclosure supervised for tamper.
  • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence.
  • Local sounder can be enabled or disabled at the FACP.
  • ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming.
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels.
  • Time-and date display field.
  • Surface mount directly to wall or to single, double, or 4in. square electrical box.
  • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting.
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel.
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs.
  • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC).
  • Up to eight ANN-80s can be connected on the ANN-BUS

Item#:
ANN-80-W
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.
The ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.)
Up to eight ANN-80s may be connected to the ANN-BUS of each FACP. No programming is required, which saves time during system commissioning.

Features

  • Listed to UL Standard 864, 9th Edition.
  • Backlit 80-character LCD display (20 characters x 4 lines).
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset.
  • Control switches can be independently enabled or disabled at the FACP.
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Keyswitch can be enabled or disabled at the FACP.
  • Enclosure supervised for tamper.
  • System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence.
  • Local sounder can be enabled or disabled at the FACP.
  • ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming.
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels.
  • Time-and date display field.
  • Surface mount directly to wall or to single, double, or 4in. square electrical box.
  • Semi-flush mount to single, double, or 4" square electrical box. Use ANN-SB80KIT for angled view mounting.
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel.
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs.
  • May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC).
  • Up to eight ANN-80s can be connected on the ANN-BUS

Item#:
ANN-80
You must be logged in to order this item. Log in here

The LCD-80F is a compact, cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the FireLite MS9200UD Series and MS-9600 Series Fire Alarm Control Panels (FACPs). The LCD-80F displays complete system point status information and includes control switches for remote control of critical system functions.

Up to 32 LCD-80Fs may be connected onto the EIA-485 terminal port of each FACP. The LCD-80F requires no programming, which saves time during system commissioning.

Features

  • 80-character Liquid Crystal Display.
  • Mimics all display information from the host panel.
  • Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key.
  • System status LEDs for Power, Alarm, Trouble, Supervisory and Alarm Silenced.
  • No programming necessary  LCD-80F connects to the terminal port (TB7)
  • Displays device type identifiers, individual point alarm, trouble or supervisory, zone and custom alpha labels.
  • Time-and-date display field.
  • Aesthetically pleasing design.
  • May be powered from the host FACP or by remote power supply (requires 24 VDC).
  • Up to 32 LCD-80F annunciators per FACP.
  • Plug-in terminal blocks for ease of installation and service

Item#:
LCD-80F
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The 5860 and 5860R are 4 x 20 LCD remote annunciators used with Silent Knight addressable fire alarm control panels. The 5860R is red and the 5860 is gray to match virtually any decor.

Features

  • 80-character backlit LCD display (4 lines with 20 characters on each line)
  • Tactile and audible feedback
  • Accepts user codes or fire fighters key
  • Install up to eight annunciators per fire alarm control panel
  • Available in red or light gray
  • UL listed

Item#:
005860R
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
The ANN-100 annunciator is a backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-100 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-100 is red.
  • Approved for use in Canada
  • Control switches for System Acknowledge, Signal Silence, Drill, and Reset
  • Control switches can be independently enabled or disabled at the FACP
  • Keyswitch enables/disables control switches and mechanically locks annunciator enclosure
  • Enclosure supervised for tamper
  • Local sounder can be enabled or disabled at the FACP
  • Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels
  • Surface mount directly to wall
  • Can be remotely located up to 6,000 feet (1,800 m) from the panel
  • Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs
Item#:
ANN-100
You must be logged in to order this item. Log in here
Item#:
ANN-I/O
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
View:
(Denotes required field.)