  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output for external trouble signals tie-in.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL602ULADA
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL1002ULADA
You must be logged in to order this item. Log in here
Remote 4-output NAC Extender, for 6.5A ttl, or 2A, max. on any 1 output. Red 14 x 16" can, connects to 120VAC, supports 24V 16Ah standby batts.  Supervised, fire bus connection. System Sensor and Wheelock NAC sync. (5/system, for 20 add’l NAC circuits ttl.). 3 Programmable relay outputs;  2 low voltage; 1 high-voltage 120V rated relay.
Item#:
GEMC-NAC7S
You must be logged in to order this item. Log in here

Altronix AL400ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC Fail-Safe and/or Fail-Secure outputs with a total of 4A @ 12VDC or 3A @ 24VDC continuous supply current. Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. This unit will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The outputs will operate in both Fail-Safe and/or Fail-Secure modes. This unit is designed to be powered by one common power source (factory installed) which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs.

Features

  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1A 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.

Item#:
AL400ULACM
You must be logged in to order this item. Log in here

  • 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate.
  • Sync protocols include Potter/Amseco, Faraday, Gentex®, System Sensor®, and CooperWheelock®.
  • Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit).
  • Compatible with 12VDC or 24VDC fire panels.
  • Output loop supervision steered to input 1 or input 2.
  • Signal circuit trouble memory (helps identify intermittent loop problems).
  • Common trouble input and output.
  • Ground fault detection.
  • Unit includes power supply, red enclosure, cam lock, and battery leads.
Item#:
AL802ULADA
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
Item#:
FN-PS776