View:

Alarm Current: 75mA (max.); 54mA (12V In), 32mA (24V In)
Dimensions: Diameter: 6.4 in. ; Width: 6.04 in. ; Depth: 1.00 in
Mounting: 4-11/16 in. square back box or inside a metal enclosure
Operating Humidity Range: 5-95% RH
Operating Temperature Range: 0 – 50° C (32 — 122° F)
Operating Voltage: Nominal: 12/24 VDC; Minimum: 10 VDC; Maximum: 35 VDC (power limited)
Standby Current: 52mA (max.); 36mA (12V In); 20mA (24V In)
Weight: 9.6 oz. (272 g)
Wiring Gauge: 14-22 AWG

Item#:
COSMOD4W
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
  • Single device for CO and smoke detection that uses less wiring and fewer junction boxes
  • Compatible with a wide range of control panels with the use of the required i4 Interface Module.
  • Sends distinct smoke and CO signals to the panel
  • Sounds Temporal 3 for smoke and Temporal 4 for CO
  • Built-in 85dB sounder
  • LEDs display both CO and smoke status
  • External IR LED provides extended range sensitivity testing
  • Versatile mounting allows for wall or ceiling placement
  • Easily replaceable electrochemical CO cell with 10-year end-of-life timer that signals the panel and chirps to alert the homeowner
  • RealTest® enables functional test using canned CO
  • Drift compensation and smoothing algorithms provide false alarm immunity
  • Compatible with SENS-RDR sensitivity tester
  • Full agency compliance with UL 268 and UL 2075
Item#:
COSMO-4W
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here

The InnovairFlex D4120 4-wire photoelectric duct smoke detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork.
This unit senses smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute, temperatures of 4°F to 158°F, and a humidity range of 0 to 95 percent (non-condensing).
A plug-in sensor head offers improved false alarm immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low-flow feature for simple maintenance.

Features

  • Photoelectric, integrated low-flow technology
  • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)
  • Versatile mounting options in square or rectangular configuration with modular construction
  • Plug-in sensor offers superb false alarm immunity and the latest sensor technology
  • Broad ranges for operating temperature (-4ºF to 158ºF) and humidity (0% to 95% non-condensing)
  • Patented sampling tube installs from front or back of the detector with no tools required
  • Increased wiring space with a newly added 3/4 inch conduit knockout
  • One easy-access Test/Reset button and improved LED status
  • Patented interconnect feature for multi-fan shutdown
  • New high contrast terminal designations
  • Built-in short circuit protection from operator wiring errors
  • Field selectable settings for configuring the detector
  • Two DPDT Form-C relay contacts
  • 24 VAC/DC or 120 VAC
  • Backward compatibility with existing Innovair products, including remote accessories

Item#:
MIRD4120
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
SPECIFICATIONS
Base Diameter: 6.2 in (157 mm)
Base Height: 0.95 in (24 mm)
Weight: 0.6 lb (274 g)
Mounting: 4 square box with or without plaster ring, minimum depth 1.5; 4 octagon box, minimum depth 1.5; 31⁄2 octagon box, minimum depth 1.5; 31⁄2 octagon box, minimum depth 1.5

Operating Temperature Range: 0°C to 49°C (32°F to 120°F)
Operating Humidity Range: 10% to 93% Relative Humidity Non-condensing
Item#:
B114LP
You must be logged in to order this item. Log in here
You must be logged in to order this item. Log in here
View:
(Denotes required field.)